Sign In | Join Free | My burrillandco.com
Home > Addressable Fire Alarm System >

Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

Shenzhen Xinhe'an Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System from wholesalers
     
    Buy cheap Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System from wholesalers
    • Buy cheap Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System from wholesalers
    • Buy cheap Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System from wholesalers

    Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

    Ask Lasest Price
    Brand Name : XHA
    Model Number : CA200
    Certification : CE
    Price : negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 500pcs/month
    Delivery Time : 7 Working days
    • Product Details
    • Company Profile

    Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System

    Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System



    Introduction


    Addressable systems are commonly used in commercial, institutional, and industrial facilities where the ability to pinpoint alarm locations is important for rapid response and effective fire management.


    This addressing capability allows the fire alarm control panel to precisely identify the location of an activated device during an alarm condition. Rather than just knowing that a fire alarm has been triggered somewhere in the building, the control panel can pinpoint the exact device that has been activated.

    The core components of an addressable fire alarm system include:

    Addressable Fire Alarm Control Panel - The main control unit that monitors and controls all the system devices.
    Addressable Initiating Devices - Things like smoke detectors, heat detectors, and manual pull stations that have built-in microprocessors to communicate with the control panel.
    Addressable Notification Appliances - Devices like sirens, strobes, and speakers that are also addressable and can be individually controlled.
    Addressable Modules - Interfaces that allow the system to monitor and control external equipment like elevators, HVAC systems, and door locks.
    The addressable devices communicate with the control panel using digital communication protocols like CLIP, MAPNET, or IDNET. This digital signaling allows for more advanced monitoring, testing, and diagnosis capabilities compared to older hardwired systems.

    Addressable fire alarm systems are commonly used in commercial, institutional, and industrial facilities where the ability to quickly identify the precise location of a fire is critical for life safety and property protection. Their enhanced capabilities make them a more robust and flexible solution over traditional systems.


    Parameters
    Product NameAddressable Fire Alarm Control PanelCapacity1-1524control points, maximum 6 loops
    CapacityMaximum 6 loopsMain power supplyAC220V± 15%, 2.5A, 50HZ.
    Battery power supplyDC 24V (2 sealed batteries: 2*12V*7Ah)Loop Bus wiredNon-polarity 2 wired.
    LCDTouch panel, Networkable, Colored LCD
    Operating EnvironmentTemperature -10°C~+50°C
    Humidity ≤95%.
    Dimentions400mm×500mm×125mm.CertificationCE



    Main Functions

    1. System self-test function. The system will test indicator light, LCD screen, sounder etc.
    2. Inquiry function. Check model type zone number, device definition etc.
    3. Event record. Record the fire alarm information and other operation record.
    4. Data sampling. Data analysis.
    5. Setting function. Set the password, time, printer information.
    6. Install and programming. Address coding, Login, Logical programming
    7. Feedback function. Give real-time feedback information after starting the equipment.
    8. Faulty alarm function. Automatically check the working status of main power supply, battery power supply, detectors , modules and report the detail fault information.




    Product Range

    Conventional Fire Alarm System
    Addressable fire alarm system
    Gas Extinguishing control system
    Beam Detector
    4 wire smoke detectors with relay output.
    2 wire Conventional smoke and heat detectors
    Explosion-proof flame detector for fire alarm system
    Standalone smoke detectors and combustable gas detector



    Service

    1. OEM &ODM service.
    2. Provide special technical support and after-sale service.
    3. 1 year warranty.
    4. Normally 15 working days lead time.

    5. Welcome sample order.


    Quality Non-Polarized 2-Wired Loop Bus for Easy Installation of Addressable Fire Alarm System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Xinhe'an Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)